ISO 50001:2018, energy management systems
Attaches to every supply point: the scope that excludes no energy type, the energy review and its significant energy uses, the data collection plan and the monitoring minimum on every line, the baseline on the top-band sites, procurement on every contract and design on every generation or storage asset. With nothing ticked these rows render as the default.
On the register, tick "ISO 50001:2018" and these rows appear on every supply point. Source framework: ISO 50001:2018, energy management systems.
How the duties attach
| Reaches | Every supply point. |
|---|---|
| every supply point | 4.3, 6.3, 6.6, 9.1.1 |
| grid electricity | 6.4, 8.3 |
| gas | 8.3 |
| solar PV | 8.2 |
| battery storage | 8.1, 8.2 |
| EV charging | 8.1 |
| diesel or standby generation | 9.1.1 |
| district heat or cooling | 8.3 |
| CHP | 8.1, 8.2 |
| interval meter | 6.4 |
| accumulation meter | 6.6 |
| sub-metered meter | 6.3 |
| unmetered meter | 6.6 |
| fixed tariff | 8.3 |
| time-of-use tariff | 6.2 |
| demand charge tariff | 6.2 |
| pass-through tariff | 6.2 |
| green tariff, certificates named tariff | 8.3 |
| green tariff, no certificate named tariff | 8.3 |
| export tariff | 8.2 |
| flat tariff | 8.3 |
| office and head office | 6.2 |
| retail unit, branch and hospitality | 6.2 |
| warehouse, distribution centre, cold store and depot | 8.1 |
| plant, bakery, workshop and laboratory | 8.1, 8.2 |
| clinic, hospital, campus and school building | 8.1 |
| car park, data room, plant room and unattended asset | 6.6 |
| top-band site | 6.2, 6.5 |
| high-band site | 6.5 |
| contract ending inside twelve months | 8.2, 8.3 |
| the register as a whole | 9.1.2, 9.3, 10.1 |
The metering minimum
Clause 9.1.1 is the row every line carries: energy performance and the EnMS monitored, measured, analysed and evaluated at planned intervals, with the significant energy uses, the relevant variables, the indicators, the effectiveness of the action plans and the consumption against the expected figure among the items monitored. Clause 6.6 names each meter in the data collection plan and asks that the measuring equipment be accurate and repeatable. An accumulation meter meets the minimum; an interval meter is what the significant energy uses and any programme need, which is why the finding names the lines where the two disagree.
The clauses, quoted
13 of 29 in the frameworkRequirement text quoted from the standards themselves, published at compliance.theartofservice.com, the same publisher as this register, read against the held text of each standard: our statement of each clause, not the instrument verbatim.
ISO 50001 4.3 Determining the scope of the energy management systemDetermine the boundaries and applicability of the EnMS, considering the issues of 4.1 and the requirements of 4.2; ensure authority to control energy efficiency, use and consumption within the scope and boundaries; do not exclude any energy type within them; maintain the scope and boundaries as documented information.
Common gap: An energy type excluded from the scope
Framework page: ISO 50001:2018
ISO 50001 6.2 Objectives, energy targets and planning to achieve themEstablish objectives at relevant functions and levels and establish energy targets (6.2.1). Objectives and energy targets shall be consistent with the energy policy, measurable if practicable, take account of applicable requirements, consider the SEUs and the opportunities from the energy review, and be monitored, communicated and updated as appropriate; retain documented information on them (6.2.2). Establish and maintain action plans stating what will be done, the resources required, who is responsible, when it will be completed and how results will be evaluated including the methods used to verify energy performance improvement; consider how the actions integrate into business processes; retain documented information on the action plans (6.2.3).
Common gap: Targets that ignore the SEUs
Framework page: ISO 50001:2018
ISO 50001 6.3 Energy reviewDevelop and conduct an energy review: analyse energy use and consumption from measurement and other data, identifying current energy types and evaluating past and current energy uses and consumption; identify the significant energy uses (SEUs); for each SEU determine relevant variables, determine current energy performance and identify the persons under the organization's control who influence or affect it; determine and prioritize opportunities for improving energy performance; and estimate future energy use and consumption. Update the review at defined intervals and after major changes to facilities, equipment, systems or energy-using processes; maintain the methods and criteria as documented information and retain its results.
Common gap: SEUs chosen without a documented significance criterion
Framework page: ISO 50001:2018
ISO 50001 6.4 Energy performance indicatorsDetermine EnPIs that are appropriate for measuring and monitoring energy performance and enable the organization to demonstrate energy performance improvement; maintain the method for determining and updating them as documented information; where data show that relevant variables significantly affect energy performance, consider that data in establishing the EnPIs; review EnPI values and compare them to the corresponding EnBs; retain documented information of EnPI values.
Common gap: EnPIs that cannot show improvement (absolute consumption with no normalization)
Framework page: ISO 50001:2018
ISO 50001 6.5 Energy baselineEstablish one or more EnBs using the information from the energy review over a suitable period; where data show that relevant variables significantly affect energy performance, normalize the EnPI values and the corresponding EnBs; revise the EnBs when the EnPIs no longer reflect energy performance, when there have been major changes to the static factors, or according to a pre-determined method; retain the EnBs, relevant variable data and modifications as documented information.
Common gap: Baseline never revised after a major static-factor change
Framework page: ISO 50001:2018
ISO 50001 6.6 Planning for collection of energy dataEnsure the key characteristics of operations affecting energy performance are identified, measured, monitored and analysed at planned intervals; define and implement an energy data collection plan appropriate to size, complexity, resources and measurement equipment, specifying the data needed to monitor the key characteristics and how and how often they are collected and retained, including the relevant variables for SEUs, energy consumption related to SEUs and the organization, operational criteria for SEUs, static factors and the data specified in action plans; review and update the plan at defined intervals; ensure measurement equipment gives accurate and repeatable data and retain documented information on the means of establishing accuracy and repeatability.
Common gap: Data plan that omits static factors
Framework page: ISO 50001:2018
ISO 50001 8.1 Operational planning and controlPlan, implement and control the processes related to the SEUs that are needed to meet requirements and implement the actions of 6.2, by establishing criteria for the processes including effective operation and maintenance of facilities, equipment, systems and energy-using processes where their absence can lead to a significant deviation from intended energy performance; communicating the criteria to the relevant persons; implementing control in accordance with the criteria; and keeping documented information to have confidence the processes were carried out as planned. Control planned changes and review the consequences of unintended changes, mitigating adverse effects; ensure outsourced SEUs or processes related to SEUs are controlled.
Common gap: Maintenance of SEU equipment left to a general schedule with no energy criteria
Framework page: ISO 50001:2018
ISO 50001 8.2 DesignConsider energy performance improvement opportunities and operational control in the design of new, modified and renovated facilities, equipment, systems and energy-using processes that can significantly impact energy performance over their planned or expected operating lifetime; where applicable incorporate the results into specification, design and procurement activities; retain documented information of design activities related to energy performance.
Common gap: Energy performance considered after the design is fixed
Framework page: ISO 50001:2018
ISO 50001 8.3 ProcurementEstablish and implement criteria for evaluating energy performance over the planned or expected operating lifetime when procuring energy-using products, equipment and services expected to have a significant impact on energy performance; when procuring products, equipment and services that have or can have an impact on SEUs, inform suppliers that energy performance is one of the evaluation criteria; where applicable define and communicate specifications for ensuring the energy performance of procured equipment and services and for the purchase of energy.
Common gap: Equipment bought on capital cost with no lifetime energy evaluation
Framework page: ISO 50001:2018
ISO 50001 9.1.1 GeneralDetermine for energy performance and the EnMS what needs to be monitored and measured, including at a minimum the effectiveness of action plans in achieving objectives and energy targets, the EnPIs, the operation of SEUs and actual versus expected energy consumption; the methods to ensure valid results; when monitoring and measurement are performed; and when the results are analysed and evaluated. Evaluate energy performance and EnMS effectiveness; evaluate energy performance improvement by comparing EnPI values against the corresponding EnBs; investigate and respond to significant deviations in energy performance and retain documented information of the investigation and response; retain documented information on monitoring and measurement results.
Common gap: Actual versus expected consumption never compared
Framework page: ISO 50001:2018
ISO 50001 9.1.2 Evaluation of compliance with legal requirements and other requirementsAt planned intervals evaluate compliance with the legal and other requirements related to energy efficiency, energy use, energy consumption and the EnMS; retain documented information on the results and any actions taken.
Common gap: Legal register maintained but compliance never evaluated
Framework page: ISO 50001:2018
ISO 50001 9.3 Management reviewTop management shall review the EnMS at planned intervals for continuing suitability, adequacy, effectiveness and alignment with strategic direction (9.3.1), considering the status of previous actions, changes in external and internal issues and related risks and opportunities, EnMS performance including trends in nonconformities and corrective actions, monitoring and measurement results, audit results and compliance evaluation results, opportunities for continual improvement including competence, and the energy policy (9.3.2); the energy performance inputs shall include the extent to which objectives and energy targets are met, energy performance and its improvement from monitoring and measurement including the EnPIs, and the status of action plans (9.3.3). Outputs shall include decisions on continual improvement opportunities and any need to change the EnMS: opportunities to improve energy performance, the energy policy, the EnPIs or EnBs, objectives, targets, action plans or other elements and actions where they are not achieved, integration with business processes, resource allocation, and improvement of competence, awareness and communication; retain documented information of the results (9.3.4).
Common gap: Review without EnPI trend or action plan status
Framework page: ISO 50001:2018
ISO 50001 10.1 Nonconformity and corrective actionWhen a nonconformity is identified: react to it, taking action to control and correct it and dealing with the consequences; evaluate the need for action to eliminate its causes so it does not recur or occur elsewhere, by reviewing it, determining its causes and determining whether similar nonconformities exist or could occur; implement any action needed; review the effectiveness of corrective action; and change the EnMS if necessary. Corrective actions shall be appropriate to the effects of the nonconformities; retain documented information of the nature of nonconformities, actions taken and the results of corrective action.
Common gap: Corrections logged with no cause analysis
Framework page: ISO 50001:2018