Energy Register

Battery storage

Storage on site: it holds energy that was imported or generated, so it carries no category of its own; the imported kWh that charges it is already counted at the connection. Its whole value is flexibility, which is why its tariff and its meter are the two things the register reads.

How the register reads it

Categoryown storage Storage on site: it holds energy that was imported or generated, so it carries no category of its own; the imported kWh that charges it is already counted at the connection.
Reportable as imported energyNo: the site's own generation or storage carries no category of its own; consumed on site it reduces the imported kWh, and any export is shown separately and never deducted.
Electrical loadYes: a demand response programme can settle it where the meter, the tariff and the class allow.
Classes that typically carry itBattery, Data room

What each regime attaches to this supply

ISO 50001ISO 50001 8.2, ISO 50001 8.1
ISO 14064-1ISO 14064-1 part 1, 5.2.3
ISO 22301ISO 22301 8.4.4, ISO 22301 8.3.2

Requirement text quoted from the standards themselves, published at compliance.theartofservice.com, the same publisher as this register, read against the held text of each standard: our statement of each clause, not the instrument verbatim.

ISO 14064-1 part 1, 5.2.3 5.2.3 Indirect GHG emissions

The organization shall apply and document a process to determine which indirect emissions to include, defining and explaining its own predetermined significance criteria in the light of the intended use (magnitude, influence, access to information, data accuracy; a risk assessment may be used), which should not be used to exclude substantial quantities or evade obligations; it shall identify and evaluate its indirect emissions against those criteria, quantify and report the significant ones, and justify any exclusion of significant indirect emissions; the criteria may be revised periodically with the revisions documented (Annex H).

Evidence an auditor accepts: Significance criteria and the evaluation of each indirect emission category against them; Justification for exclusions
Common gap: Significance decided after seeing the numbers
Framework page: ISO 14064-1:2018
ISO 22301 8.3.2 Identification of strategies and solutions

Identify candidate strategies and solutions by the extent to which they meet the requirement to continue and recover prioritized activities within the identified time frames and agreed capacity, protect those activities, reduce the likelihood of disruption, shorten its duration, limit its impact on products and services, and provide for adequate resources.

Evidence an auditor accepts: Option analysis scoring candidates against each identification factor; Evidence time frame and capacity requirements came from the BIA; Coverage of likelihood reduction options, not recovery options alone
Common gap: Candidates assessed on cost alone at the identification stage, collapsing identification into selection
Framework page: ISO 22301:2019
ISO 22301 8.4.4 Business continuity plans

Document and maintain business continuity plans that guide teams through response and recovery, collectively containing the actions to continue or recover prioritized activities within predetermined time frames, the means of monitoring the disruption and the response, the pre defined thresholds and process for activating the response, procedures to deliver products and services at agreed capacity, and how the immediate consequences are managed with regard to individual welfare, prevention of further loss and environmental impact; each plan must state purpose, scope and objectives, the roles and responsibilities of the implementing team, the actions implementing the solutions, the supporting information needed to activate, operate, coordinate and communicate including activation criteria, internal and external interdependencies, resource requirements, reporting requirements and a stand down process, and must be usable and available at the time and place it is needed.

Evidence an auditor accepts: Plan set with each plan carrying every required element; Activation criteria and thresholds stated in the plan itself; Interdependency and resource sections reconciled to the BIA
Common gap: Plans that cover activation and response but have no stand down, so the organization never formally returns to normal
Framework page: ISO 22301:2019
ISO 50001 8.1 Operational planning and control

Plan, implement and control the processes related to the SEUs that are needed to meet requirements and implement the actions of 6.2, by establishing criteria for the processes including effective operation and maintenance of facilities, equipment, systems and energy-using processes where their absence can lead to a significant deviation from intended energy performance; communicating the criteria to the relevant persons; implementing control in accordance with the criteria; and keeping documented information to have confidence the processes were carried out as planned. Control planned changes and review the consequences of unintended changes, mitigating adverse effects; ensure outsourced SEUs or processes related to SEUs are controlled.

Evidence an auditor accepts: Operating and maintenance criteria for SEUs; Change control records; Controls over outsourced SEUs
Common gap: Maintenance of SEU equipment left to a general schedule with no energy criteria
Framework page: ISO 50001:2018
ISO 50001 8.2 Design

Consider energy performance improvement opportunities and operational control in the design of new, modified and renovated facilities, equipment, systems and energy-using processes that can significantly impact energy performance over their planned or expected operating lifetime; where applicable incorporate the results into specification, design and procurement activities; retain documented information of design activities related to energy performance.

Evidence an auditor accepts: Design reviews recording energy performance consideration over the lifetime
Common gap: Energy performance considered after the design is fixed
Framework page: ISO 50001:2018

Register every supply point that carries it

Paste the list; every line of this supply carries these rows beside its meter, its tariff and its kWh. Eight supply points free, no account.

Build my energy register